6000 Not enough memory in line #n (x)
6001 Invalid preprocess type x in line #n
6002 Invalid postprocess type x in line #n
6003 Invalid origin code x in line #n
6004 Incorrect number of parameters in line #n
6005 Unrecognized command in line #n
6006 Command error(s) detected processing FS file x
An error was encountered processing the FS file.
6007 WARNING: invalid display-box number d ignored in line #n
6008 WARNING: file not found (d) in line #n of s
6009 WARNING: duplicate command ignored, line #n of s
An error was encountered processing the FS file but it was not sufficiently serious to reject the fax send request. The transmission may not have been completed as expected. The 6008 warning is only issued if the Ignore Missing COPIAFACTS run-time option is set.
6011 License to use FFWIN/FFCLIENT not enabled in line #n of file %s
6012 License to use FFMERGE not enabled in line #n of file %s
6013 License to use F7GCOVER not enabled in line #n of file %s
The FS file was generated from a CopiaFacts add-on product which has not been licensed for use on this system.
6014 Outbound call aborted because of simultaneous inbound call
An inbound call was detected after an outbound operation had been scheduled for transmission on the same line, but just in time to stop the outbound call continuing, and to reset it to be picked up later or by another line.
6015 WARNING: invalid delete option ignored in line #n
The $delete_option keyword was invalid or not correctly spelled.
6016 FFWIN/FFCLIENT licensed for only n users in line #n of file x
6017 License to use Document Converter not enabled in line #n of file x
The FS file was generated from a CopiaFacts add-on product which has not been licensed for use on this system.
6018 Outbound call aborted because no free E1 telephony channel
There was no Dialogic telephony channel available on which to place the call. This sometimes occurs when a telephony channel is slow to clear or has become unavailable either on the board or at the CO.
6019 Invalid date value x in line #n of file x ignored
The $fax_send_date was invalid.
6020 Include file not found {-12}
6021 Required library FFPDF.DLL not found or failed to load {-11}
6022 Exception while reading GCT watermark file {-10}
6023 Exception in F7GCOVER {-9}
6024 Error writing GCT output file {-8}
6025 Exception while writing GCT output file {-7}
6026 Error reading GCT input TIFF file {-6}
6027 Invalid GCT output filename {-5}
6028 No free cache entry for GCT watermark
6029 GCT Watermark file not found {-3}
6030 GCT file has insufficient data {-2}
6031 GCT file not found for conversion {-1}
6032 Graphical cover creation failed (code n) for x
An error was detected in F7GCOVER.DLL while processing graphical customization or TIF file transformation. The negative numbers shown in { } are the error values returned by F7GCOVER when called from the GCSINGLE utility.
6033 Invalid e-mail option in line #n
6034 Alternate body/text not preceded by body/text in line #n
6035 Missing $email_address command
6036 Cannot have both alt-body and alt-text in line #n
6037 Cannot have both body and text in line #n
A syntax error was detected in processing an e-mail FS file
6038 Multiple 'infobox' pre-process lines at line #n
6039 Multiple 'infobox' post-process lines at line #n
Only a single infobox process of each type is allowed. You can instead chain multiple infobox files to process additional tasks.
6040 Invalid convert options keyword in line #n
An incorrect keyword was given on a $convert_options command.
6041 Invalid TOSEND directory number in line #n
6042 Retry delays class letter must be A..H in line #n
6043 Invalid characters in delay string in line #n
6044 Partial-retry max time must be >=0, less than 2 days, in line #n
6045 Partial-retry minimum completion invalid in line #n
A syntax error was detected in processing smart-retry settings
6046 Invalid/missing DNS file x in line #n
There was a problem processing a do-not-send file specified on $dns_file.
6047 Pre- or Post-Process command count exceeded in line #n
There is a limit of 8 on the number of pre and post process commands
6048 Pre- and Post-Processes specify both DOS and NT for file x
A legacy DOS pre- or post-process remains active
6049 Warning: original ACTIVE file for FS x not found (n)
An access-control file in the ACTIVE folder has probably been manually deleted. Be sure to investigate the cause if this error occurs frequently.
Topic url: http://www.copia.com/support/refmanual/index.html?fsfileerrors(6xxx).htm